FD580 Ultrasonic Flaw Detector
The FD580 portable flaw detector has a high-capacity lithium-ion battery and can therefore be operated up to 8 hours without needing to be recharged. A high-resolution color LCD display makes this instrument very operator-friendly.

Features
|

- Automatic transducer calibration, zero offset and/or velocity
- Automatic gain control, peak hold and peak memory
- Automatic display of precise flaw location
- Ten independent setups; any criterion can be input freely, no test block required for proceeding
- Manual B-Scan
- High-speed capture and very low noise
- Two gate settings and alarm indication
- Automatic generation of DAC and AVG curves
- Display-freeze capability
- Angles and K-values may be inputted
- Lock/unlock system parameters
- Auto power-off and screen savers
- Electronic clock calendar
- Solid metal housing
- High contrast viewing of the waveform from bright, direct sunlight to complete darkness and easy to read from all angles
- Large memory of 300 A-Scan waveforms and 30,000 thickness values.
- RS232 communication interface ; reports can be exported to Excel
- Powerful embedded software which can be online-updated
- Li battery
Specifications
|
Function
|
Technical Data
|
|
Scanning
|
Range: 2.5mm to 10,000mm
Stage: 2.5, 5, 10, 20, 30, 40, 50, 60, 70, 80, 90, 100, 150, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1,000, 2,000, 3,000, 4,000, 5,000, 6,000, 7,000, 8,000, 9,000 and 10,000mm
Step:0.1mm (from 2.5 mm to 99.9mm),1mm (from 100mm to10,000mm)
|
|
Display delay
|
D-delay range: -20 to +3400µs
Stage: -20, -10, 0.0, 10, 20, 50, 100, 150, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1,000, 1,500, 2,000, 2,500, 3,000 and 3,400µs.
Step: 0.1µs (from -20ms to +999.9ms), 1µs (from 1,000ms to 3,400ms)
|
|
Probe delay
|
P-delay range: 0.0 to 99.99µs
Step: 0.01µs
|
|
Sound velocity in material
|
Sound velocity range: 1,000 to 9,999m/s
Seven fixed velocities or stages: 2,260, 2,730, 3,080, 3,230, 4,700, 5,900 and 6,300
Step: 1m/s
|
|
Working methods
|
Single probe (P/R), dual probe (transceiver) or transmission probe
|
|
Frequency ranges
|
Low frequency: 0.2 to 1MHz, middle frequency: 0.5 to 4MHz, high frequency: 2 to 20MHz, three steps optional
|
|
Gain
|
Range: 0 to 110dB
Step: 0.0, 0.2, 0.5, 1, 2, 6 and, 12d
|
|
Linear suppression
|
0% to 80% of screen height, step:1%
|
|
Vertical linear error
|
Less than 3%
|
|
Horizontal linear error
|
Less than 1% within scanning range
|
|
Detection sensitivity margin
|
³60dB
|
|
Dynamic scope
|
³32dB
|
|
Alarm
|
Traveling-wave alarm, evanescent-wave alarm
|
|
Monitoring gate
|
Two gates represented by a horizontal thick line with adjustable start point, width and height.
Starting point(mm): horizontal pixels from 0 to 208 with the display value relating to scanning range.
Step(mm): quantity corresponding to one pixel (relating to scanning range)
Width(mm): horizontal pixels from 4 to 212 with the display value relating to scanning range.
Step(mm): quantity corresponding to one pixel (relating to scanning range)
Height: vertical scale from 2% to 90%
Step: 1%
|
|
Display
|
EL highlight dot matrix
4 background colors availab
|
|
A-Scan display
|
Full screen or partial
Freezing and unfreezing of image
|
|
Wave display
|
All wave
|
|
Detecting channels
|
10
|
|
Data storage
|
300 A-Scan waveforms (30 for each channel)
30,000 thickness values (300 groups)
|
|
Communication port with PC
|
RS232
|
|
Measuring Units
|
mm or in; time in µs
|
|
Power adaptor
|
Input: 100 to 240VAC @ 50 Hz to 60Hz
Output: 9 to12VDC @ 3 to 4A
|
|
Power
|
Four 3.6V lithium batteries, 4,000mAhr
|
|
Ambient temperature
|
0 to 40⁰C
|
|
Ambient humidity
|
20 to 90%RH
|
|
Interface
|
BNC
|
|
Dimensions of processor
|
240 × 173 × 50mm
|
|
Weight of processor
|
2.2kg
|
|
|
|
   
|